Recruiting

Observational Study

Sponsor:

Sysmex America, Inc.

Code:

NCT01140763

Conditions

Breast Neoplasms

Breast Diseases

Eligibility Criteria

Sex: All

Age: 18+

Healthy Volunteers: Not accepted

Interventions

Sysmex's 5-blade lymph node cutter

Study Details

Brief summary:

This is a study to evaluate the incidence of sampling bias during pathologic assessment of sentinel lymph nodes (SLN) when they are cut at a certain thickness (1 mm) and the tissue slices are completely analyzed by histopathology (at 200 µm sections). The sponsor and investigators would like to determine how often small cancer deposits are present in one slice but not the other. The data will provide an empirical estimate of the incidence of tissue sampling bias inherent in using different tissue sections for analysis. The data will also show how varying degrees of detail in evaluating the sentinel lymph nodes (SLN) with histopathology methods will impact the degree of agreement.

Conditions

Breast Neoplasms

Breast Diseases

Study ID

NCT01140763

Start date

Aug, 2010

Status verified date

Aug, 2010

Completion date

Mar, 2012

Anticipated

Primary completion date

Dec, 2011

Anticipated

Eligibility Criteria

Eligibility Criteria

Sex: All

Age: 18+

Healthy Volunteers: Not accepted

Inclusion Criteria:

  • Male or female
  • 18 years of age or older
  • Diagnosed pre-surgically with T1 or T2 breast cancer and scheduled for surgery including sentinel lymph node dissection
  • Subjects (or the subject's legal representative) who have read, understood (to the best of their ability) and signed the informed consent form.

Exclusion Criteria:

  • Subjects diagnosed pre-surgically with large or locally advanced (T3 \& T4) breast cancer
  • Pregnant subjects, confirmed by interview with either subject or treating physician
  • Subjects diagnosed with inflammatory breast cancer
  • Subjects diagnosed with ductal carcinoma in situ (DCIS) when breast conservation is to be done
  • Subjects with clinically suspicious, palpable axillary lymph nodes
  • Subjects previously treated for or previously diagnosed with another type of invasive cancer. Subjects with skin cancer (basal cell and squamous cell carcinoma) may be included, except for subjects diagnosed with melanoma
  • Subjects who have received pre-operative systemic therapy
  • Subjects who are incapable of providing written informed consent
  • Subjects who have been judged to be an inappropriate candidate by any medical care provider (e.g., surgeon, oncologist or pathologist).

Study Design

Enrollment

75 participants

Anticipated

Interventions and Outcome Measures

Arms

Sysmex's 5-blade cutter.

Interventions

Sysmex's 5-blade lymph node cutter

A maximum of 3 dissected sentinel lymph nodes (SLN) per subject will be included in this study. Lymph nodes will be sliced at 1 mm intervals with Sysmex's 5-blade lymph node cutter. Alternate slices will be allocated to either "reference" histopathology or "test" histopathology. Three serial sections will be cut every 200 µm (level): the 1st section per level for hematoxylin \& eosin (H\&E), the middle section of the 3rd level for Immunohistochemistry (IHC)(pan- cytokeratin antibody clone AE1/AE3). All other sections will be blanks in case further analysis is needed.

Primary outcome measure

  • Prospectively assess the agreement of histopathology results on tissue sections taken from different slices of SLNs removed using standard SLN biopsy procedures. [ Time Frame: 9 months ]

Central Contacts and Locations

Locations

Breast Care Specialist, PC

Recruiting

Allentown, Pennsylvania, United States, 18104

Contacts

Principal Investigator:

Mark A Gittleman, MD

More Information

Sponsor

Sysmex America, Inc.

Last update posted

Aug 30, 2010

Last verified

Aug, 2010

Keywords

  • metastasis

Trial information was received from ClinicalTrials.gov and was last updated on 2026-09-08. This information was provided to ClinicalTrials.gov by Sysmex America, Inc. on 2010-08-30.