Brief summary:

Transcatheter aortic valve implantation (TAVI) serves a growing spectrum of patients with symptomatic severe aortic stenosis (AS). Approximately 80% of surgical aortic valve replacements are performed using a bioprosthesis. Durability of surgical bioprostheses varies according to patient age at the time of implantation, prosthesis type and size, among other factors. TAVI has become an established treatment option for patients with a degenerated surgical aortic bioprosthesis. The time from index surgical aortic valve replacement (SAVR) to bioprosthetic valve degeneration is typically 8-10 years. TAVI in this setting has shown favorable outcomes. Balloon-expandable and self-expanding transcatheter heart valves (THVs) can both be used for the treatment of a degenerated surgical aortic bioprosthesis and have specific advantages and limitations. Valve-in-valve TAVI may be associated with coronary obstruction, THV migration, paravalvular regurgitation, and prosthesis-patient mismatch.

Objective:

To compare valve-in-valve TAVI with balloon-expandable SAPIEN/MYVAL THV series versus the self-expanding EVOLUT THV series. The primary analysis evaluates device success at 30 days in the primary cohort. Continued enrollment will additionally support a secondary comparison of the safety and efficacy of the SAPIEN and MYVAL THV series.

Study design: International multicenter randomized study with 1:1 randomization to TAVI with the EVOLUT THV series or the SAPIEN/MYVAL THV series.

Study population:

The primary cohort comprises 440 patients with a failing surgical aortic bioprosthesis (aortic stenosis with or without aortic regurgitation) selected for transfemoral TAVI by heart-team consensus. Enrollment of the primary cohort has been completed.

The continued-enrollment cohort comprises 160 additional patients and will increase the total study population to 600 patients, with a target distribution of 300 patients treated with the EVOLUT THV series, 150 with the SAPIEN THV series, and 150 with the MYVAL THV series.

Investigational intervention:

Transfemoral valve-in-valve TAVI with a balloon-expandable SAPIEN or MYVAL THV series or a self-expanding EVOLUT THV series.

Main study parameters/endpoints:

1. Primary endpoint is device success at 30 days

Defined by:
  • Absence of procedural mortality; AND
  • Technical success at exit from the procedure room defined as freedom from mortality, successful access, delivery of the device and retrieval of the delivery system, correct positioning of a single prosthetic heart valve into the proper anatomical location, and freedom from surgery or intervention related to the device or to a major vascular or access-related, or cardiac structural complication; AND
  • Intended performance of the prosthetic heart valve (no severe prosthesis-patient mismatch and mean aortic valve gradient <20 mmHg or peak velocity <3 m/s, Doppler velocity index ≥0.25, and no moderate or severe prosthetic valve regurgitation).

Severe prosthesis-patient mismatch is defined as an indexed effective orifice area (EOAi) ≤0.65 cm²/m² (≤0.55 cm²/m² if BMI ≥30 kg/m²).
2. Safety endpoint at 1 year defined by the composite of all-cause death, disabling stroke, rehospitalization for heart failure, or valve-related problems.
3. Secondary objective is comparison of the safety and efficacy of the SAPIEN versus MYVAL THV series, including the incidence of moderate or severe prosthesis-patient mismatch.

The continued-enrollment cohort is designed to support this comparison.

Conditions

Valve Heart Disease

Study ID

NCT04843072

Start date

May 1, 2021

Status verified date

Oct, 2026

Completion date

May 1, 2029

Anticipated

Primary completion date

Jun 1, 2028

Anticipated

Eligibility Criteria

Eligibility Criteria

Sex: All

Age: 18+

Healthy Volunteers: Not accepted

Inclusion Criteria:

  • Age ≥ 18 years
  • Failing surgical aortic bioprosthesis requiring valve replacement and eligible for transfemoral TAVI with balloon expandable or self-expanding platform per heart team consensus based on multi-modality imaging assessment (including echocardiography and multidetector CT).
  • Written informed consent

Exclusion Criteria:

  • Not eligible for Transfemoral TAVI with EVOLUT, SAPIEN or MYVAL THV series
  • Multi-valve defects requiring intervention
  • Clinically unstable and/or inotropic/vasopressor /mechanical support.
  • Known mural thrombus in the left ventricle
  • Presence of a mechanical aortic valve
  • History of recent (within 1 month) stroke or TIA

Study Design

Enrollment

600 participants

Anticipated

Allocation

Randomized

Intervention Model

Parallel Assignment

Primary purpose

Treatment

Interventions and Outcome Measures

Arms

experimental: EVOLUT R/PRO/PRO+/FX bioprosthesis

Study subjects will receive a self-expanding valve from the EVOLUT THV series (EVOLUT R/PRO/PRO+/FX).

active comparator: SAPIEN 3/Ultra or MYVAL/Octacor/Octapro bioprosthesis

Study subjects will receive a balloon-expandable valve from either the SAPIEN THV series (SAPIEN 3, SAPIEN 3 Ultra) or the MYVAL THV series (Myval Octacor, Myval Octapro).

Interventions

EVOLUT R/PRO/PRO+/FX bioprosthesis

To compare EVOLUT R/PRO/PRO+/FX bioprosthesis versus Edwards SAPIEN 3/Ultra bioprosthesis or Myval/Octacor/ Octapro in failing surgical bioprostheses

Edwards Sapien S3/Ultra bioprosthesis

Edwards Sapien S3/Ultra bioprosthesis

MYVAL/Octacor/Octapro bioprosthesis

MYVAL/Octacor/Octapro bioprosthesis

Primary outcome measure

  • Device success [ Time Frame: 30 days post transcatheter valve implantation ]

Central Contacts and Locations

Central contacts

Rutger-Jan Nuis, MD, PhD

+31614858291r.nuis@erasmusmc.nl

Locations

Cedars Sinai

Recruiting

Los Angeles, California, United States, 90048

Principal Investigator:

Raj Makkar, MD

More Information

Sponsor

Erasmus Medical Center

Last update posted

Oct 13, 2026

Last verified

Oct, 2026

Trial information was received from ClinicalTrials.gov and was last updated on 2026-10-14. This information was provided to ClinicalTrials.gov by Erasmus Medical Center on 2026-10-13. Recruitment status is synced daily from ClinicalTrials.gov and may not reflect the sponsor's current status. Confirm during your call.