Recruiting

AC 12L ECG

Sponsor:

University of Oklahoma

Code:

NCT05617001

Conditions

Arrhythmia

Eligibility Criteria

Sex: All

Age: 18+

Healthy Volunteers: Accepted

Interventions

Kardia 12L

Study Details

Brief summary:

AliveCor (www.alivecor.com) has developed an ECG device (KardiaMobile) that interfaces with iOS and Android smartphones and tablets. This ECG consists of a lightweight hardware case with two metal electrodes that can snap onto the back of the phone and a software application. By holding the right finger(s) on the right electrode and the left finger(s) on the left electrode, an electrical circuit is completed and a lead-I, 30 second rhythm strip is created. KardiaMobile and a newer device, KardiaMobile 6L, were approved by FDA for ECG rhythm recording. Recently, AliveCor developed a new device: Kardia 12L to record 12-lead ECGs. However, the data generated from the new device has not yet been validated for accuracy. The specific aim of this study is to evaluate the accuracy and safety of the AC 12L ECG System. The ECGs collected by the AC 12L ECG System will be compared to simultaneous standard- of-care 12-lead ECG, recorded using the GE CardioSoft 12-lead ECG System. The ECGs will be analyzed for accuracy based on statistical difference using root-mean-square error, and cross correlation between the simultaneous 10 second recordings as well as the median beats of all 12 leads.

Conditions

Arrhythmia

Study ID

NCT05617001

Start date

Oct 4, 2022

Status verified date

Feb, 2024

Completion date

Dec, 2024

Anticipated

Primary completion date

Aug, 2024

Anticipated

Eligibility Criteria

Eligibility Criteria

Sex: All

Age: 18+

Healthy Volunteers: Accepted

Inclusion Criteria:

  • Male or female patients 18 years or older
  • Ability to remain supine for a conventional 12 lead AliveCor 12L ECG recording for approximately 15 minutes

Exclusion Criteria:

  • Open chest wounds or recent (<30 days) surgery to the chest or abdomen
  • Absence of any limb that would require modification of the lead set-up

Study Design

Enrollment

200 participants

Anticipated

Intervention Model

Single group

Primary purpose

Diagnostic

Interventions and Outcome Measures

Interventions

Kardia 12L

The purpose of this study is to collect clinical validation data to support an FDA submission for a 510(k) for the Kardia 12L hardware which enables the simultaneous diagnostic quality recording of all 6 limb leads and any chest lead. We will be recording both Leads V1 and V2 in a sequential fashion along with the V4 and Limb leads and a simultaneous 12-lead ECG to validate the hardware and a Deep Neural Network model which expands the 5 leads into a complete 12-lead ECG. The 12-lead ECG used for validation of the recordings and the 12-lead synthesis model is the GE Cardiosoft System which is FDA cleared.

Primary outcome measure

  • Agreement on QRS width between Kardia 12L and ECG [ Time Frame: 30 seconds ]
  • Agreement on PR interval between Kardia 12L and ECG [ Time Frame: 30 seconds ]
  • Agreement on AT interval between Kardia 12L and ECG [ Time Frame: 30 seconds ]

Central Contacts and Locations

Central contacts

Locations

University of Oklahoma Health Sciences Center

Recruiting

Oklahoma City, Oklahoma, United States, 73104

Contacts

More Information

Sponsor

University of Oklahoma

Last update posted

Feb 28, 2024

Last verified

Feb, 2024

Trial information was received from ClinicalTrials.gov and was last updated on 2026-09-10. This information was provided to ClinicalTrials.gov by University of Oklahoma on 2024-02-28.