Recruiting

CorMatrix Cor TRICUSPID

Sponsor:

CorMatrix Cardiovascular, Inc.

Code:

NCT05742906

Conditions

Tricuspid Valve Disease

Tricuspid Valve Insufficiency

Eligibility Criteria

Sex: All

Age: 0+

Healthy Volunteers: Not accepted

Interventions

Tricuspid valve replacement with the Cor TRICUSPID ECM Valve

Study Details

Brief summary:

The goal of this pivotal study is to demonstrate the safety and performance of the Cor TRICUSPID ECM (extracellular matrix) Valve (or Cor PEDIATRIC Tricuspid ECM Valve) for the surgical management of tricuspid valve disease and dysfunction in adult and pediatric patients. The main question(s) it aims to answer are:

  • whether the device may be implanted successfully and safely, and
  • whether the device effectively treats tricuspid valve disease and dysfunction through 12 months

Participants will undergo:

  • preoperative evaluation
  • tricuspid valve replacement with the Cor TRICUSPID ECM Valve
  • postoperative evaluation, including at hospital discharge, 30 days, 6 months, and 12 months, and then annually thereafter through 5 years

Conditions

Tricuspid Valve Disease

Tricuspid Valve Insufficiency

Study ID

NCT05742906

Start date

Aug 10, 2022

Status verified date

May, 2025

Completion date

Dec, 2026

Anticipated

Primary completion date

Dec, 2025

Anticipated

Eligibility Criteria

Eligibility Criteria

Sex: All

Age: 0+

Healthy Volunteers: Not accepted

Inclusion Criteria:

1. Patient with a regurgitant or absent tricuspid valve requiring surgical treatment including those patients having concomitant cardiac procedures
2. Patient/authorized legal guardian understands the nature of the procedure, is willing to comply with associated follow-up evaluations, and provides written informed consent and the pediatric patient (if applicable) provides written assent (if able) prior to procedure
3. Patient/patient's authorized legal guardian is geographically stable (or willing to return for required study follow-up) and understands and is willing to fulfill all of the expected requirements of this clinical protocol
4. Patients where the Cor TRICUSPID ECM Valve will be the physiological right-sided atrioventricular (AV) valve

Exclusion Criteria:

1. Tricuspid annulus too small (< 10mm) to accommodate the Cor TRICUSPID ECM Valve
2. Left ventricular ejection fraction (LVEF) < 25%
3. Mean pulmonary pressure ≥ 50mmHg or pulmonary vascular resistance greater than 6 Woods Units
4. Emergency cardiac procedure. An example would be a person requiring resuscitation and in cardiogenic shock. An unscheduled or unplanned emergency surgery
5. Cardiac transplant patient
6. Acute transmural myocardial infarction (MI) within 7 days of enrollment that results in cardiogenic shock
7. Patients with a single ventricle where the Cor TRICUSPID ECM Valve would be the systemic AV valve
8. Documented primary coagulopathy or uncorrected platelet disorder, including thrombocytopenia (absolute platelet count < 30k). Patient can be enrolled regardless of these parameters if in the opinion of the Investigating Surgeon the coagulopathy can be adequately reversed by transfusions. An example would be the reversal of thrombocytopenia by transfusion of platelets
9. Documented evidence of intrinsic hepatic disease (defined as liver enzyme values (aspartate aminotransferase (AST), alanine aminotransferase (ALT), or total bilirubin) that are > 5 times the upper limit of reference range within 30 days of enrollment, except in association with acute/reversible decompensation as determined by the Investigator)
10. Documented evidence of significant renal dysfunction (serum creatinine > 4.0mg/dl or GFR< 30 on the modified Schwartz formula)
11. Stroke within 30 days prior to enrollment
12. Major or progressive non-cardiac disease (liver failure, renal failure, cancer (CA)) that has a life expectancy of less than one year
13. Known cancer (cancer-free ≤ 1 year; does not include non-metastatic basal cell carcinoma or cervical carcinoma) and/or undergoing treatment including chemotherapy and radiotherapy
14. Hematological disorders (e.g., aplastic anemia) or patients taking bone marrow suppressant drugs
15. Known sensitivity to porcine materials
16. Contraindication to anticoagulation/antiplatelet therapy (aspirin (ASA) and/or Plavix)
17. Patients who are pregnant (method of assessment Investigator's discretion)
18. Patients who are currently enrolled in another investigational study or registry that would directly impact the treatment or outcome of the current study, without CorMatrix written approval

Study Design

Enrollment

92 participants

Anticipated

Allocation

Non randomized

Intervention Model

Parallel Assignment

Primary purpose

Treatment

Interventions and Outcome Measures

Arms

other: Group A: Adults treated with SIS 1.0 Cor TRICUSPID ECM Valve

Adults (>/= 21 years of age) treated with the SIS 1.0 Cor TRICUSPID ECM Valve

other: Group B: Pediatrics treated with SIS 1.0 Cor TRICUSPID ECM Valve

Pediatrics (<21 years of age) treated with SIS 1.0 Cor TRICUSPID ECM Valve

other: Group C: Adults treated with SIS 2.0 Cor TRICUSPID ECM Valve

Adults (>/= 21 years of age) treated with the SIS 2.0 Cor TRICUSPID ECM Valve

other: Group D: Pediatrics treated with SIS 2.0 Cor TRICUSPID ECM Valve

Pediatrics (<21 years of age) treated with SIS 2.0 Cor TRICUSPID ECM Valve

Interventions

Tricuspid valve replacement with the Cor TRICUSPID ECM Valve

Tricuspid valve replacement with the Cor TRICUSPID ECM Valve for the surgical management of tricuspid valve disease or dysfunction.

Primary outcome measure

  • Safety Outcome - Procedural Success [ Time Frame: 30 days ]
  • Effectiveness Outcome - Individual Patient Success [ Time Frame: 6 months ]
  • Effectiveness Outcome - Individual Patient Success [ Time Frame: 12 months ]

Central Contacts and Locations

Central contacts

Locations

St Francis Hospital

Recruiting

Indianapolis, Indiana, United States, 46237

Contacts

Principal Investigator:

Marc Gerdisch, MD

Columbia University Irving Medical Center/New York Presbyterian

Recruiting

New York, New York, United States, 10032

Contacts

More Information

Sponsor

CorMatrix Cardiovascular, Inc.

Last update posted

Sep 2, 2025

Last verified

May, 2025

Keywords

  • Tricuspid Valve Disease
  • Tricuspid Valve Dysfunction
  • Tricuspid Valve Regurgitation
  • Tricuspid Valve Replacement

Trial information was received from ClinicalTrials.gov and was last updated on 2026-09-09. This information was provided to ClinicalTrials.gov by CorMatrix Cardiovascular, Inc. on 2025-09-02.