Recruiting

Sirolimus-Coated Balloon

Sponsor:

Concept Medical Inc.

Code:

NCT06271590

Conditions

Coronary Artery Disease

Native Coronary Artery Stenosis

Cardiovascular Diseases

Eligibility Criteria

Sex: All

Age: 18 - 70+

Healthy Volunteers: Not accepted

Interventions

Sirolimus Drug Coated Balloon

Drug eluting stents (DES)

Study Details

Brief summary:

This is a multicenter, randomized, single-blind pivotal study to evaluate the safety and efficacy of the MagicTouchTM Drug coated balloon in treatment of small vessels in patients with coronary artery disease. The objective is to establish the safety and efficacy of the Magic TouchTM Drug coated balloon in treatment of small vessels (≤2.75 mm).

A total of 1605 subjects will be enrolled in a maximum of 50 study sites located in North America. Additional sites located in Europe and South America may also participate in the study, with non-US sites contributing a maximum of \~50% of enrollees.

Conditions

Coronary Artery Disease

Native Coronary Artery Stenosis

Cardiovascular Diseases

Study ID

NCT06271590

Start date

May 20, 2025

Status verified date

Sep, 2025

Completion date

Nov, 2031

Anticipated

Primary completion date

Nov, 2028

Anticipated

Eligibility Criteria

Eligibility Criteria

Sex: All

Age: 18 - 70+

Healthy Volunteers: Not accepted

Clinical Inclusion Criteria:

1. Adult patient with an indication for PCI due to stable angina, NSTEACS, post-infarction angina or silent ischemia (in absence of symptoms a visually estimated target lesion diameter stenosis of ≥70%, a positive non-invasive stress test, FFR ≤0.80, or non-hyperemic pressure ratio \[NHPR\] ≤0.89 must be present)
2. Subject is ≥18 and <80 years old
3. Subject is willing to comply with all protocol-required follow-up evaluations and provides written informed consent

Angiographic Inclusion Criteria:
4. Target reference vessel diameter (visual estimation) ≤2.75 mm
5. Successful lesion preparation (residual stenosis <30%), without flow-limiting complications (no or slow flow, dissection etc.)
6. Target lesion(s) in a native coronary artery
7. Up to two small vessel target lesions in two different vessels
8. Target lesion length (visual estimation): ≥6.0 and ≤34.0 mm and can be covered by a single 40 mm balloon
9. Target lesion diameter stenosis (visual estimation) >30% and <100% with Thrombolysis in Myocardial Infarction (TIMI) flow grade ≥2

Clinical Exclusion Criteria:

1. Planned (staged) intervention in the target vessel
2. ST-segment-elevation MI within 48 hours prior to index procedure
3. Subjects with acute cardiac decompensation or cardiogenic shock
4. Subject with a life expectancy of less than 24 months
5. Impaired renal function (glomerular filtration rate \[GFR\] <30 mL/min)
6. Documented left ventricular ejection fraction (LVEF) ≤30%
7. Known allergies to acetylsalicylic acid, clopidogrel, prasugrel, ticagrelor, heparin, contrast medium, sirolimus or similar drugs (i.e., ABT-578 \[Zotarolimus\], biolimus, tacrolimus)
8. Relative or absolute contraindication to dual antiplatelet therapy (DAPT) for at least 1 month (e.g., planned surgeries that cannot be delayed)
9. Subject has an indication for chronic oral anticoagulation treatment and a contraindication for concomitant treatment with a P2Y12 inhibitor
10. If femoral access is planned, significant peripheral arterial disease which precludes safe insertion of a 6F sheath
11. Hemoglobin <9 g/dL
12. Platelet count <100,000 cells/mm3 or >700,000 cells/mm3
13. White blood cell count <3,000 cells/mm3
14. Active infection undergoing treatment
15. Clinically significant liver disease
16. Cerebrovascular accident (CVA) within 3 months or has any permanent neurological defect as a result of CVA
17. Subject is receiving oral or intravenous immunosuppressive therapy (e.g., inhaledsteroids are not excluded) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus, but not including diabetes mellitus)
18. Subject is unlikely to comply with the follow up requirements, per investigator's assessment
19. Subject currently enrolled in other investigational device or drug trial in which primary endpoint has not been reached
20. Pregnant and/or breast-feeding females or females who intend to become pregnant during the time of the study

Angiographic Exclusion Criteria:

All exclusion criteria apply to the target lesion(s) or target vessel(s)
21. Re-stenotic lesion(s), whether due to percutaneous old balloon angioplasty (POBA) or prior stenting
22. True bifurcation lesion (lesion involves both main and side branch>2.5 mm) with planned treatment of both branches per investigator assessment
23. Angiographic evidence of thrombus in the target vessel
24. Myocardial bridging
25. Target lesion is heavily calcified
26. Diffuse distal disease to target lesion with impaired runoff, TIMI flow <2
27. Non-target lesion in the target vessel requiring PCI

Note: Non-target vessel PCI is allowed at the time of index procedure if performed prior to study intervention and if successful and uncomplicated. For target lesions located in branches of the three main vessels (left anterior descending artery \[LAD\], left circumflex artery \[LCx\], right coronary artery \[RCA\]), the term target vessel refers to the branch and not the main vessel.

Study Design

Enrollment

1605 participants

Anticipated

Allocation

Randomized

Intervention Model

Parallel Assignment

Primary purpose

Treatment

Interventions and Outcome Measures

Arms

experimental: MagicTouch Sirolimus-Coated Balloon (SCB)

Magic TouchTM is a Sirolimus Coated Balloon catheter intended to be used in coronary applications, treats the atherosclerosis of the coronary arteries by eluting the immunosuppressant agent Sirolimus without leaving behind a metallic scaffold.

active comparator: Drug eluting stents (DES)

Everolimus eluting stents (EES) or Zotarolimus eluting stents (ZES)

Interventions

Sirolimus Drug Coated Balloon

Magic TouchTM (Concept Medical) is a semi-compliant sirolimus drug coated balloon (SCB) for PCI, based on a polymer-free and nanocarrier based drug delivery technology.

Drug eluting stents (DES)

For subjects randomized to the control group (DES), the treating physician will choose an FDA cleared DES (ZES or EES) and follow lesion preparation and stent deployment according to the Instructions per use (IFU) and institutional practices.

Primary outcome measure

  • Target lesion failure (TLF) [ Time Frame: within 12 months ]

Central Contacts and Locations

Locations

Clearwater Cardiovascular and Interventional Consultants

Recruiting

Clearwater, Florida, United States, 33756

Contacts

Atlanticare Regional Medical Center

Recruiting

Pomona, New Jersey, United States, 08401

Contacts

Icahn School of Medicine at Mount Sinai/ Mount Sinai Hospital

Recruiting

New York, New York, United States, 10029

Contacts

Montefiore Medical Center

Recruiting

The Bronx, New York, United States, 10467

Contacts

Baylor Scott & White The Heart Hospital - Plano

Recruiting

Plano, Texas, United States, 75093

Contacts

More Information

Sponsor

Concept Medical Inc.

Last update posted

Sep 11, 2025

Last verified

Sep, 2025

Keywords

  • Drug coated balloon
  • Sirolimus coated balloon
  • De Novo
  • Magic Touch
  • SCB
  • Concept Medical
  • Small Vessel
  • MAGICAL SV

Trial information was received from ClinicalTrials.gov and was last updated on 2026-09-10. This information was provided to ClinicalTrials.gov by Concept Medical Inc. on 2025-09-11.