Recruiting

RMS vs. Xience

Sponsor:

Teleflex

Code:

NCT07258290

Conditions

Coronary Disease

Heart Diseases

Cardiovascular Diseases

Arteriosclerosis

Arterial Occlusive Diseases

Eligibility Criteria

Sex: All

Age: 18 - 70+

Healthy Volunteers: Not accepted

Interventions

Freesolve RMS

Xience DES

Study Details

Brief summary:

The objective of this study is to assess the safety and efficacy of the Freesolve resorbable magnesium scaffold (RMS) in the treatment of subjects with up to two de novo lesions in native coronary arteries compared to the Xience coronary drug-eluting stent (DES) system

Conditions

Coronary Disease

Heart Diseases

Cardiovascular Diseases

Arteriosclerosis

Arterial Occlusive Diseases

Study ID

NCT07258290

Start date

Jun 11, 2026

Status verified date

Nov, 2025

Completion date

Jun, 2033

Anticipated

Primary completion date

Jun, 2029

Anticipated

Eligibility Criteria

Eligibility Criteria

Sex: All

Age: 18 - 70+

Healthy Volunteers: Not accepted

Clinical Inclusion Criteria:

1. Subject is ≥ 18 years and ≤ 80 years of age
2. Subject has provided written informed consent as approved by the Ethics Committee / Institutional Review Board (IRB) of the respective clinical site prior to the study related procedures
3. Subject is eligible for PCI according to the applicable guidelines
4. Subject is an acceptable candidate for coronary artery bypass surgery
5. Subjects with stable or unstable angina pectoris, documented silent ischemia/abnormal physiologic testing or hemodynamically stable non-ST elevation myocardial infarction (NSTEMI) patients without angiographic evidence of thrombus at target lesion

Note: STEMI patients may be eligible for the study for treatment of selected non-culprit lesions, if:
  • Subject and target lesion(s) meet all inclusion and no exclusion criteria and consent occurs at least ≥ 72 hours after successful treatment of the culprit lesion(s) \[lesion(s) causing the acute STEMI\];
  • Subject is hemodynamically stable with documented declining cardiac biomarkers;
  • Target lesion(s) to be treated are not located in the culprit vessel(s) and are not culprit lesion(s)
6. Subject is eligible for Dual Antiplatelet Therapy (DAPT) with aspirin plus either clopidogrel, prasugrel, ticagrelor or ticlopidine
7. Documented left ventricular ejection fraction (LVEF) ≥ 30% within 6 months prior to or during the procedure (prior to randomization)
8. Subject is willing and able to comply with protocol requirements, including completion of study visits for the duration of the study

Angiographic Inclusion Criteria:

1. Subjects with a maximum of two single de novo target lesions each in separate native coronary arteries
2. Target vessel must have a reference diameter between 2.5-4.2 mm by operator visual estimation, which may be assisted by Quantitative Coronary Angiography (QCA) / Intravascular Ultrasound (IVUS) / Optical Coherence Tomography (OCT)
3. Target lesion(s) must be ≤ 36 mm in length by operator visual estimation, which may be assisted by QCA / IVUS / OCT, (or < 20 mm for target lesion(s) to be treated with a study device < 3.0 mm in diameter) and must be amenable to treatment with a single study device
4. Target lesion stenosis ≥ 50% and < 100% by operator visual estimation, which may be assisted by QCA / IVUS / OCT. Target lesion stenosis < 70% by visual estimation, should have clinical justification for treatment as per local standards.
5. Target lesion must have a Thrombolysis in Myocardial Infarction (TIMI) flow ≥ 1

Clinical Exclusion Criteria:

1. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study
2. Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with STEMI < 72 hours prior to the index procedure Note: Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment
3. Subject has undergone prior PCI within the target vessel during the last 12 months prior to the index procedure or prior PCI within a non-target vessel < 72 hours prior to the index procedure
4. Subject is on dialysis or has impaired renal function (serum creatinine > 2.5 mg/dL or 221 µmol/L, determined within 7 days prior to the index procedure)
5. Subject has a known allergy to contrast medium that cannot be adequately premedicated, or any known allergy to aspirin, P2Y12 inhibitors, both heparin and bivalirudin, sirolimus, everolimus (or similar limus drugs), poly L-lactide, the scaffold material (magnesium, aluminum, tantalum), or Xience stent material (cobalt, chromium, tungsten, nickel, methacrylic polymer, and fluoropolymer)
6. Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted)
7. Life expectancy less than 1 year
8. Planned surgery or dental surgical procedure within 6 months after index procedure, unless DAPT can be maintained
9. In the investigator's opinion subject will not be able to comply with the follow-up requirements
10. Subjects under oral anticoagulation therapy (OAC) prior to index procedure unless DAPT + OAC (i.e., triple therapy) can be maintained for a minimum of 1 month
11. Subject has had a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure
12. Subject with active bleeding disorder, active coagulopathy, or any other reason, who is ineligible for DAPT
13. Subject is currently participating or plans to participate in another study with an investigational device or an investigational drug
14. Subject has known severe aortic or mitral valve stenosis/insufficiency or has previously undergone transcatheter aortic valve replacement (TAVR)

Angiographic Exclusion Criteria:

1. Target vessel has been previously treated and the target lesion is within 5 mm proximal or distal to the previously treated lesion
2. Left main coronary artery disease
3. Target lesion is totally occluded (100% stenosis)
4. Thrombus in target vessel
5. Future planned staged PCI either in target or non-target vessel
6. Ostial target lesion within the left anterior descending (LAD), left circumflex (LCX), or right coronary artery (RCA) (within 5.0 mm of vessel origin)
7. Target lesion involves a side branch ≥ 2.0 mm in diameter that requires a two-device strategy after pre-dilatation
8. Target lesion is located in or supplied by an arterial or venous bypass graft
9. Target lesion with excessive tortuosity proximal to or within the lesion based on visual estimation or heavily calcified target lesion which cannot be adequately pre-dilated by a non-compliant and/or cutting/scoring balloon as described in angiographic exclusion criteria 10
10. Target lesion requires treatment with a device other than the non-compliant balloon and/or cutting/scoring balloon prior to scaffold/stent placement (including but not limited to atherectomy devices, intravascular lithotripsy, drug-coated balloons, etc.)
11. Target vessel was treated with brachytherapy any time prior to the index procedure.
12. Unsuccessful pre-dilatation, defined as residual stenosis > 20% (by visual estimation) and/or angiographic complications (e.g., distal embolization, side branch closure, flow-limiting dissections)

Study Design

Enrollment

1859 participants

Anticipated

Allocation

Randomized

Intervention Model

Parallel Assignment

Primary purpose

Treatment

Interventions and Outcome Measures

Arms

experimental: Freesolve RMS

Intervention with a Freesolve Sirolimus Eluting Coronary Resorbable Magnesium Scaffold (RMS) System

active comparator: Xience DES

Intervention with a Xience Everolimus Eluting Stent System

Interventions

Freesolve RMS

Freesolve Sirolimus-Eluting Coronary Resorbable Magnesium Scaffold (RMS) System, a drug-eluting balloon-expandable resorbable scaffold

Xience DES

Xience Everolimus Eluting Stent System

Primary outcome measure

  • Target Lesion Failure (TLF) rate at 12 months post-index procedure [ Time Frame: 12 months ]

Central Contacts and Locations

Central contacts

BIOMAG-III Project Manager

1-866-246-6990biomag_us@teleflex.com

Locations

MedStar Washington Hospital Center

Recruiting

Washington D.C., District of Columbia, United States, 20010

Charleston Area Medical Center

Recruiting

Charleston, West Virginia, United States, 25304

More Information

Sponsor

Teleflex

Last update posted

Aug 31, 2026

Last verified

Nov, 2025

Keywords

  • Resorbable Magnesium Scaffold
  • Sirolimus
  • RMS
  • Drug eluting absorbable metal scaffold

Trial information was received from ClinicalTrials.gov and was last updated on 2026-09-09. This information was provided to ClinicalTrials.gov by Teleflex on 2026-08-31.